Sub-Zero Wine Storage Error Code 10 C 00: Condenser Thermistor Open
10 C 00 reports an open condenser thermistor; a 30-second breaker reset and retest is the listed step.
Sub-Zero IC-24CI column refrigerator-freezer — model notes, common issues and what to have ready before booking.
A quick set of checks before booking can help with a 24-inch column refrigerator-freezer. Confirm the set temperatures look right on the display, and see whether both doors close squarely against their seals. Check the floor beneath the cabinet for water, and note whether the compressor is running almost constantly. Look inside for frost on the freezer walls and feel whether the fresh-food section is cold near the top and bottom. The Sub-Zero IC-24CI is an older model still worth repairing. A short description of the cubes or the cabinet noise helps too. Households in the metro areas we cover should enter IC-24CI and what they found in the booking form.
| Model | IC-24CI |
|---|---|
| Appliance | 24-inch column refrigerator-freezer |
| Common symptoms | Frost on freezer walls, water beneath the cabinet, compressor running almost constantly, uneven cold in the fresh-food section. |
| What you can check | Confirm the set temperatures on the display and that both doors close squarely on their seals. Check the floor for water, look for freezer frost and feel the fresh-food section top and bottom. |
| When to call a technician | Arrange a technician visit if the compressor runs almost constantly, frost builds or water sits beneath the cabinet. Tell them what you found and describe any cube or noise changes. |
IC-24CI is a Sub-Zero 24″ column refrigerator-freezer. It is no longer sold new, but units in homes are still serviced. The model number is printed on the rating label, usually on a side wall or the ceiling inside the fresh-food section, or behind the base grille; match it letter for letter before booking.
Check the rating label on a side wall or the ceiling inside the fresh-food section, or behind the base grille. Use the full number, including any letters at the end.
Yes. We book in-home visits for this model in the Miami, New York, Houston, Los Angeles and San Diego metro areas. Add the model number and the symptom to the booking form.
Note how long the temperature has been off and whether the freezer side is affected too.
10 C 00 reports an open condenser thermistor; a 30-second breaker reset and retest is the listed step.
Sub-Zero code 15 1 00: refrigerator compressor relay stuck open. Try a 30 second breaker reset, then call service if it returns.
On Classic (BI) and Designer units, 20 2 00 reports a defrost bi-metal stuck open.
Code 30 8 05 reports no ice maker fill signal on Classic (BI) and a missing water valve in signal on Designer units.
35 1 00 reports an open zone 1 evaporator fan. Cycle the breaker and retest before calling.
Code 40 1 00 flags a Zone 1 stepper current fault on Designer wine storage and Designer (Integrated) units.
45 1 00 reports an open circuit in the main refrigerator lights. Reset the breaker for 30 seconds and retest.
Code 90 5 80 means no keypad communications on Classic (formerly BI) Series units; reset the breaker for 30 seconds.
Note how long the temperature has been off and whether the freezer side is affected too.
Model-information disclaimer. Confirm your exact model number and specifications with your appliance documentation before booking a repair. Model pages are for identification and compatibility reference.
Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.
Fields marked with * are required.