Sub-Zero Refrigerator Error Code 10 1 00: Cabinet Thermistor Open
10 1 00 comes from the 2009 service manual for the older Built-In (BI) Series and means the refrigerator cabinet thermistor is open.
Sub-Zero BI-30UG over-and-under refrigerator-freezer — model notes, common issues and what to have ready before booking.
With the glass-front version of an over-and-under unit, the first clue is often what the owner sees rather than hears. Frost patterns inside the freezer, water that appears near the bottom of the cabinet or an ice maker that quietly stops are typical early signs. A louder or more frequent compressor run can come next. The Sub-Zero BI-30UG is an older model and still worth repairing when the cabinet is sound. Before calling, note which area changed first, whether the change came suddenly and whether the sound has shifted. Households in the metro areas we serve can list the model number BI-30UG and that first clue in the booking form.
| Model | BI-30UG |
|---|---|
| Appliance | 30-inch glass-door over-and-under refrigerator-freezer |
| Common symptoms | Freezer frost patterns, water near the bottom of the cabinet, an ice maker that quietly stops, and a louder or more frequent compressor run. |
| What you can check | Before calling, note which area changed first, whether the change came suddenly, and whether the sound has shifted. |
| When to call a technician | If the frost, bottom-of-cabinet water, stopped ice maker or louder compressor persists, schedule a service visit while the cabinet is sound. Name the first clue when you book. |
BI-30UG is a Sub-Zero 30″ over-and-under refrigerator-freezer (glass door). It is no longer sold new, but units in homes are still serviced. The model number is printed on the rating label, usually on a side wall or the ceiling inside the fresh-food section, or behind the base grille; match it letter for letter before booking.
Check the rating label on a side wall or the ceiling inside the fresh-food section, or behind the base grille. Use the full number, including any letters at the end.
Yes. We book in-home visits for this model in the Miami, New York, Houston, Los Angeles and San Diego metro areas. Add the model number and the symptom to the booking form.
Note how long the temperature has been off and whether the freezer side is affected too.
10 1 00 comes from the 2009 service manual for the older Built-In (BI) Series and means the refrigerator cabinet thermistor is open.
Sub-Zero code 15 1 00: refrigerator compressor relay stuck open. Try a 30 second breaker reset, then call service if it returns.
On Classic (BI) and Designer units, 20 2 00 reports a defrost bi-metal stuck open.
On the older Classic (BI) series, 30 8 00 reports an open circuit in the ice accessories.
35 A 36 means the air filter fan is faulty on Classic (formerly Built-In) series units.
40 1 38 reports a refrigerator stepper valve communication fault on Classic (formerly Built-In) series units.
44 0 00 flags an open circuit on the glass door heater connector. Try a 30-second breaker reset, then book service.
45 1 00 reports an open circuit in the main refrigerator lights. Reset the breaker for 30 seconds and retest.
50 U 80 means the water flow meter is not detected on Built-In (BI) units.
Code 60 1 02 flags a communication error with the refrigerator variable speed compressor on Classic (BI) models.
Code 90 0 70 is a flash failure on Classic (formerly BI) series refrigerators and freezers.
95 1 25 is a refrigerator diagnostics failure from the 2009 Built-In (BI) series manual. No owner steps are listed.
Note how long the temperature has been off and whether the freezer side is affected too.