Sub-Zero Refrigerator Error Code 10 1 00: Cabinet Thermistor Open
10 1 00 comes from the 2009 service manual for the older Built-In (BI) Series and means the refrigerator cabinet thermistor is open.
Sub-Zero BI-48SID side-by-side refrigerator — model notes, common issues and what to have ready before booking.
Diagnosis on a 48-inch side-by-side with an internal dispenser usually begins by separating the ice and water circuit from the cooling circuit, since both share the cabinet. The Sub-Zero BI-48SID is an older model that is still worth repairing. A dispenser that has stopped points toward the water side, while frost in the freezer or a warm fresh-food area points toward cooling and airflow. Note which function failed first and whether the two problems began together. Mention whether the water supply was changed or disconnected recently. Households across the cities we cover should list the model number BI-48SID and that sequence in the booking form.
| Model | BI-48SID |
|---|---|
| Appliance | 48-inch side-by-side with dispenser |
| Common symptoms | Stopped dispenser, freezer frost, warm fresh-food area, two problems that may have started together. |
| What you can check | Note which function failed first and whether the two problems began together. Mention if the water supply was changed or disconnected recently. |
| When to call a technician | A dispenser that has stopped points to the water side, while frost or warmth points to cooling and airflow. Arrange a technician visit and share the sequence. |
BI-48SID is a Sub-Zero 48″ side-by-side refrigerator. It is no longer sold new, but units in homes are still serviced. The model number is printed on the rating label, usually on a side wall or the ceiling inside the fresh-food section, or behind the base grille; match it letter for letter before booking.
| Dimensions | The cabinet is 48 inches wide. Nominal height is 84 inches, with a ±1/2-inch height tolerance. |
|---|---|
| Capacity | The 2015 guide lists 18.6 cu. ft. of refrigerator capacity. The 2015 guide lists 9.6 cu. ft. of freezer capacity. |
| Power | The freezer defrost heater is rated at 450 W in the May 2015 service table. |
| Installation | Shipping weight for the stainless steel version is 656 lb. |
| Features | The refrigerator uses fan-assisted off-cycle defrost. The freezer uses adaptive defrost with a five-minute compressor delay after defrost. |
The SID suffix marks the internal-dispenser version, so the dispenser sits inside the cabinet rather than on the door, which is the difference from the BI-48SD external-dispenser model. Its 18.6-cubic-foot refrigerator and 9.6-cubic-foot freezer, as the 2015 guide lists them, set the capacity. A 656-pound shipping weight for the stainless version means installers should plan for help on delivery. The listing is marked discontinued, so check parts against the exact model before ordering.
A dispenser or ice production problem on this internal-dispenser model usually traces to the water line, the fill valve or a dispenser switch, and a technician checks the supply before the control. A compressor or fan running loud or nonstop often points to the fan that moves air across the coils, which the technician listens for at the back. A fresh-food section that will not reach the set temperature is most often tied to the fan-assisted off-cycle defrost or a damper, so note whether the fresh-food side or the freezer side runs warm. Water inside or under the unit usually comes from a blocked defrost drain or a dispenser line leak, and the technician checks both. The freezer defrost heater is rated at 450 W in the May 2015 service table, so a heater check is a reasonable early step.
Check the rating label on a side wall or the ceiling inside the fresh-food section, or behind the base grille. Use the full number, including any letters at the end.
Yes. We book in-home visits for this model in the Miami, New York, Houston, Los Angeles and San Diego metro areas. Add the model number and the symptom to the booking form.
Note how long the temperature has been off and whether the freezer side is affected too.
10 1 00 comes from the 2009 service manual for the older Built-In (BI) Series and means the refrigerator cabinet thermistor is open.
Sub-Zero code 15 1 00: refrigerator compressor relay stuck open. Try a 30 second breaker reset, then call service if it returns.
On Classic (BI) and Designer units, 20 2 00 reports a defrost bi-metal stuck open.
On the older Classic (BI) series, 30 8 00 reports an open circuit in the ice accessories.
35 A 36 means the air filter fan is faulty on Classic (formerly Built-In) series units.
40 1 38 reports a refrigerator stepper valve communication fault on Classic (formerly Built-In) series units.
44 0 00 flags an open circuit on the glass door heater connector. Try a 30-second breaker reset, then book service.
45 1 00 reports an open circuit in the main refrigerator lights. Reset the breaker for 30 seconds and retest.
50 U 80 means the water flow meter is not detected on Built-In (BI) units.
Code 60 1 02 flags a communication error with the refrigerator variable speed compressor on Classic (BI) models.
Code 90 0 70 is a flash failure on Classic (formerly BI) series refrigerators and freezers.
95 1 25 is a refrigerator diagnostics failure from the 2009 Built-In (BI) series manual. No owner steps are listed.
Note how long the temperature has been off and whether the freezer side is affected too.